Commercial dehumidifier sizing: AHAM vs saturation pints, model by model
November 5, 2026 2026-11-05 13:57Commercial dehumidifier sizing: AHAM vs saturation pints, model by model
Commercial dehumidifier sizing: AHAM vs saturation pints, model by model
Commercial dehumidifier sizing gets confusing when a “250-pint” unit and a “110-pint” unit can be the same machine. The difference is the test condition. This page is the model-by-model sizing companion: AHAM vs saturation ratings for ten commercial and crawl space dehumidifiers Germaphobix sells, so you can compare like with like and size by the job. For the lab-condition and pump deep dive (two Waykar SKUs), see Commercial dehumidifier pints: AHAM vs saturation, and when you need a pump.
The two ratings in one paragraph
AHAM pints per day (PPD) are measured at 80°F and 60% relative humidity. That is close to a typical conditioned basement, crawl space, or building in the later stages of drying. Saturation pints are measured in hot, wet air. Manufacturers use 90°F/90% RH (AlorAir) or 95°F/90% RH (AVAHUM, ANDTE), which looks more like the first day of a fresh water loss in summer. The same compressor removes far more water in hot, saturated air, so the saturation number is always the larger one.
Published AHAM vs saturation ratings
| Model | AHAM (80°F/60%) | Saturation | Ratio | Coverage (mfr) | Drain |
|---|---|---|---|---|---|
| AlorAir Sentinel HDi65S | 55 PPD | 120 PPD | 2.2× | ~1,300 sq ft | Built-in pump |
| AlorAir Galaxy 60 | 60 PPD | 145 PPD | 2.4× | ~1,800 sq ft | Gravity |
| AlorAir Storm LGR 850X WiFi | 85 PPD | 180 PPD | 2.1× | ~2,300 sq ft | See product page |
| Waykar 180 Pint with Pump (PDGT701BA) | 90 PPD | 180 PPD (95°F/90%) | 2.0× | See product page | Pump |
| AlorAir Storm Ultra 90 WiFi | 90 PPD | 190 PPD | 2.1× | ~2,600 sq ft | Pump |
| ANDTE DE190P | 90 PPD | 190 PPD (95°F/90%) | 2.1× | up to 6,500 sq ft | Pump |
| AlorAir Sentinel HDi90 | 90 PPD | 198 PPD | 2.2× | See product page | Built-in pump |
| AVAHUM AM260 | 110 PPD | 250 PPD (95°F/90%) | 2.3× | up to 8,000 sq ft | Drain hose |
| AlorAir Sentinel HDi120 | 120 PPD | 235 PPD | 2.0× | up to 3,300 sq ft | Built-in pump |
| AVAHUM AM305 | 130 PPD | 320 PPD (95°F/90%) | 2.5× | up to 9,000 sq ft | Drain hose |
Coverage figures are manufacturer claims and aren’t measured the same way across brands. Notice that AlorAir lists the HDi120 at 3,300 sq ft while AVAHUM lists a similar AHAM class at 8,000 sq ft. Compare AHAM pints first and treat square footage as a rough guide.
What the ratio tells you
Across these ten machines, the saturation rating is 2.0 to 2.5 times the AHAM rating.
- If a listing gives only a saturation number, divide by about 2 to 2.5 for a realistic expectation at 80°F/60% RH.
- A machine listed as “180 pints AHAM” next to a 90-PPD AHAM competitor of the same size almost certainly means saturation, mislabeled as AHAM. Ask for the test condition.
Sizing by job type
- Crawl spaces and basements (long-term humidity control): Size on AHAM. Most crawl spaces up to about 1,300 to 1,800 sq ft are covered by the 55 to 60 PPD AHAM class (Sentinel HDi65S, Galaxy 60). Choose a built-in pump when there’s no floor drain or the drain is uphill. See crawl space dehumidifier with pump: specs that matter.
- Water-damage restoration (first days of a loss): Saturation numbers matter more early on, but conditions fall toward AHAM as the structure dries. Bid and plan on AHAM so the job doesn’t stall in the final days. LGR units like the Storm LGR 850X and Storm Ultra 90, or the Ebac Orion, keep pulling water as air gets drier. Pair them with air movers and HEPA air scrubbers.
- Warehouses, garages, and large open spaces: High-capacity units in the 110 to 130 PPD AHAM range (AVAHUM AM260/AM305) cover the most area per unit. Running a drain hose to a floor drain avoids pump maintenance.


What is the difference between AHAM and saturation dehumidifier ratings?
AHAM pints per day are measured at 80°F and 60% relative humidity. Saturation pints are measured in hot, wet air (90°F/90% or 95°F/90% RH, depending on the manufacturer). The same machine removes roughly 2 to 2.5 times more water at saturation than at AHAM conditions.
Which rating should I use to size a commercial dehumidifier?
Use AHAM for crawl spaces, basements, and ongoing humidity control, and for planning the later stages of a restoration job. Saturation ratings only describe performance in very hot, soaked air.
How do I convert saturation pints to AHAM pints?
For the commercial and crawl space units Germaphobix sells, divide the saturation rating by about 2 to 2.5. If the manufacturer publishes an AHAM number, use that instead.
Do I need a dehumidifier with a pump?
Choose a built-in pump when there’s no floor drain or the drain point is higher than the unit, which is common in crawl spaces and basements. Gravity drain-hose models are simpler when you have a floor drain.
Is a bigger saturation number always better?
No. Compare AHAM ratings and the test condition first. Two machines with the same AHAM rating can show very different saturation numbers because manufacturers test at different temperatures.
Shop: All dehumidifiers · AlorAir · AVAHUM · ANDTE · Questions? (866) 312-1777